| This product has permanent anti-static function
because it uses conductive static network formed at the
interface of plastic particles.Its appearance looks like
the pattern of marble.So iit has good decoration effect
and is wide usedfor program machine room, computer room
, control room of electric power clean and purijfication
workshop of telecommunication,electric power,electronics,micro-electron
and medicine etc. industries where it is necessay to prevent
from static. |
| Technical
parameters |
| size£º600¡Á600¡Á2.0 600¡Á600¡Á2.5
600¡Á600¡Á3.0 |
| technical indexes£º£¨¼ûÏÂ±í£© |
| corrosion£º |
| HCL |
ok |
NaOH aqueous solution |
ok |
| Alcohol |
ok |
Gasoline |
ok |
| Acetone |
ok |
Ordinal detergent |
ok |
|
| Name of item |
Systemresistor |
Full-life |
Rate of size change
at heating |
Amount of wear |
Combustion property |
Starting voltage |
| Standard |
DIN51953 |
GJB2605-1996
5000V~50V |
GB4085-83 |
GB4085-83 |
GB4609-84
FV-O |
SJ/T10664-1996 |
| index |
104~106 ¦¸(conductive)
106~108¦¸(anti-static) |
<2sec |
<0.25% |
<0.02g/cm2 |
<10sec |
<100V |
 |
 |
 |
| SJ-9301 |
SJ-9302 |
SJ-9303 |
 |
 |
 |
| SJ-9304 |
SJ-9305 |
SJ-9306 |
 |
 |
 |
| SJ-9307 |
SJ-9602 |
SJ-9603 |
| Brief Introduction to Construction |
£¨1£© the requirements of foundation
1. The fondation should be waterstone ground , ceramic
tile ground ,wooden ground or cement mortar ground.
2. The ground should be smooth and level and no
uneven .Its unevenness should be less than 0.2%.
3. The ground should have enough strength and no
the phenomenon of sanding and separation.
4. The ground should be dry.It is necessary for
new ground to dry about 30 days.
|
(2) procedure of construction
clean the ground ->spread the earthing conductive
net ->lead the earthing line -> coat strong
adhesive ->coat conductive adhesive_> spread
floor => weld the aps of floor ->L clean its
surface ->inspect its properties
|
(3)Maintenance of floor
1. It is not permitted that the sharp and rough
heavy matters scribe and drag on the surface of
floor and that personnel who wear shoes with nails
walk on the floor. The floor should be kept clean,smooth
and level.
2. It is not permitted that the chairs which have
black rubber cushion put on its surface in order
to avoid black sulfide polluting its surface.
3. If there are oil or dirty on its surface,it maybe
cleaned with cleanser or washing powder.If there
is scribed sign in local position,it may be sanded
with fine abrasive paper.
4. If there is heavy oil and dirty caused by installation,our
factory has special washer to clean them.
5. Our factory also has anti-static wax that can
be used to maintain the floor.In general,it should
be coated one time within six months.If the personnel
who walk on the floor are busy, it should coated
one time within three months.
|
|